In this article
- Key takeaways
- How a spring sets a relief valve’s opening pressure
- Why spring rate decides overpressure
- Worked example: a 20 bar relief valve spring
- Tolerances: what moves the set pressure
- Relaxation, temperature and material choice
- Ends, squareness and guiding
- Check valve and regulator springs
- What to send for a relief valve spring quote
- Frequently asked questions
- References
Cover image: an AI-generated illustration based on a photo of our small compression springs; the valve parts are generic and not a specific product.
A relief valve spring is the compression spring that holds the poppet, disc or ball of a pressure relief valve on its seat. Its installed force, divided by the seat area, sets the pressure at which the valve opens. Its rate decides how much further the pressure must rise to push the valve fully open. Get either number wrong and the valve opens too early, too late or not far enough.
This guide is written for valve makers and maintenance buyers who order relief, check and regulator valve springs. It explains the force balance, shows why spring rate controls overpressure, works through a 20 bar valve spring, and lists the tolerances that move the set pressure. It also covers relaxation, material choice and what to put on the drawing.
Key takeaways
- Set pressure = installed spring force ÷ seat area. A 10 mm seat set at 20 bar needs 157 N at installed height.
- Rate controls overpressure. As the poppet lifts, the spring compresses further and its force rises. A soft spring keeps that rise small. Allowable overpressure is normally 3 to 10 percent for gases and 10 to 25 percent for liquids [1].
- Specify force at installed height, not just free length and rate. In our example, a 0.5 mm free length error moves the set pressure by 3.3 percent; a 5 percent rate error moves it by 5 percent.
- Relaxation lowers the set point. Every 1 percent of force a spring loses in service lowers the opening pressure by 1 percent. Low stress, presetting and the right wire for the temperature keep it small.
- Ends and squareness matter. A tilted spring pushes the poppet sideways and can cause leakage or uneven lift; closed and ground ends are the norm.
How a spring sets a relief valve’s opening pressure
Most pressure relief valves are spring operated [2]. In the basic design, the closing force on the disc comes from a spring, typically carbon steel, and its compression can be adjusted with a spring adjuster to change the pressure at which the disc lifts [1].
The force balance at the moment of opening is simple:
p × A = F1, so p_set = F1 / A
where p is the inlet pressure, A is the seat area (π × ds² / 4 for a seat diameter ds) and F1 is the spring force at its installed height.

This quick-reference table gives the spring force needed at installed length for common seat diameters. Force scales with the square of the seat diameter, so a small seat change has a large effect.
| Seat diameter | Seat area | Force per bar | Force at 10 bar | Force at 20 bar | Force at 50 bar |
|---|---|---|---|---|---|
| 3 mm | 7.1 mm² | 0.71 N | 7 N | 14 N | 35 N |
| 5 mm | 19.6 mm² | 1.96 N | 20 N | 39 N | 98 N |
| 8 mm | 50.3 mm² | 5.03 N | 50 N | 101 N | 251 N |
| 10 mm | 78.5 mm² | 7.85 N | 79 N | 157 N | 393 N |
| 12 mm | 113.1 mm² | 11.31 N | 113 N | 226 N | 565 N |
| 16 mm | 201.1 mm² | 20.11 N | 201 N | 402 N | 1,005 N |
| 20 mm | 314.2 mm² | 31.42 N | 314 N | 628 N | 1,571 N |
| 25 mm | 490.9 mm² | 49.09 N | 491 N | 982 N | 2,454 N |
The spring’s installed force is its rate k times its preload deflection, the distance it is compressed from free length when the valve is closed. The adjusting screw sets that installed length. So the spring maker controls the rate and the free length, and the valve maker sets the final preload on the test stand.
Set pressure is not the only pressure that matters. Valve standards and suppliers also use these terms [3]:
| Term | Meaning | Where the spring comes in |
|---|---|---|
| Set pressure | Pressure at which the valve starts to lift | Installed force F1 |
| Overpressure | Rise above set pressure needed to reach rated lift and capacity | Spring rate k and lift |
| Reseating pressure | Pressure at which the valve closes again | Spring force near the seat, plus valve trim |
| Blowdown | Set pressure minus reseating pressure, as a share of set | Mostly valve trim; spring must be stable |
Blowdown is usually stated as a share of set pressure and can vary roughly 2 to 20 percent [2]. For compressible fluids it is usually under 10 percent, and for liquids it can reach 20 percent [1].
Why spring rate decides overpressure
Once the poppet lifts, the spring is compressed further by the lift, and its force rises by k × lift. Ignoring flow forces, the inlet pressure needed to hold the valve at that lift rises by:
Δp = k × lift / A
The lower the rate, the smaller the pressure rise for the same lift. That is why relief valve springs are usually long and soft for their force, with a large preload deflection. The table uses our worked example: a 10 mm seat (A = 78.5 mm²), set at 20 bar (157 N), with 1.5 mm lift.
| Spring rate | Preload deflection at 157 N | Force rise at 1.5 mm lift | Pressure at full lift | Rise above set |
|---|---|---|---|---|
| 5 N/mm | 31.4 mm | 7.5 N | 20.95 bar | 4.8 % |
| 10.45 N/mm | 15.0 mm | 15.7 N | 22.00 bar | 10.0 % |
| 20 N/mm | 7.9 mm | 30.0 N | 23.82 bar | 19.1 % |
| 30 N/mm | 5.2 mm | 45.0 N | 25.73 bar | 28.6 % |
| 60 N/mm | 2.6 mm | 90.0 N | 31.46 bar | 57.3 % |

Real valves are not this simple. Shrouds, skirts and huddling chambers are added so that fluid forces help the disc open quickly within a small overpressure [1]. Pop-action safety valves snap to full lift, while relief valves for liquids open roughly in proportion to the overpressure [2]. But in every design the spring rate adds to the pressure rise, so the valve designer’s rate limit is a real number that belongs on the spring drawing.
Worked example: a 20 bar relief valve spring
Example scenario (an illustration, not a customer record): a direct-acting relief valve with a 10 mm seat, set at 20 bar, 1.5 mm lift at rated flow, and a spring rise of no more than 10 percent of set pressure. The bore around the spring allows a 21 mm outside diameter.
Step 1, force at set: A = π × 10² / 4 = 78.54 mm². At 20 bar (2.0 MPa), F1 = 2.0 × 78.54 = 157.1 N.
Step 2, rate limit: 10 percent of 157.1 N is 15.7 N over 1.5 mm lift, so k ≤ 10.5 N/mm.
Step 3, spring design. With the standard relations k = G·d⁴ / (8·D³·Na) and τ = Kb·8·F·D / (π·d³) [4], one solution in chrome silicon wire (G = 79.3 GPa) is:
| Value | Result |
|---|---|
| Wire diameter d | 2.8 mm |
| Mean coil diameter D / outside diameter | 18.0 mm / 20.8 mm |
| Spring index C = D/d | 6.43 |
| Active coils Na / total coils | 10 / 12 (closed and ground ends) |
| Rate k | 10.45 N/mm |
| Free length L0 | 60.0 mm |
| Preload deflection at 157.1 N | 15.0 mm |
| Installed length (valve closed) | 45.0 mm |
| Length at full lift / force | 43.5 mm / 172.8 N |
| Solid height | 33.6 mm |
| Bergsträsser factor Kb | 1.22 |
| Stress at full lift | 440 MPa |
| Estimated tensile strength, Cr-Si 2.8 mm | 1,766 MPa |
| Stress at full lift / tensile strength | 0.25 |
| Force and stress at solid | 275.8 N / 703 MPa (0.40 of tensile) |
The working stress is low on purpose: a quarter of tensile strength at full lift. Low stress keeps relaxation small, and relaxation is what drifts the set pressure down over years of service. The spring also has about 9.9 mm of travel left between full lift and solid, so it cannot go solid if the poppet overshoots. The tensile strength is an estimate from the usual relation Sut = 1,974 / d^0.108 MPa for chrome silicon wire; real values come from the wire certificate. Our chrome silicon springs article compares this wire with music wire and oil-tempered wire.
The same valve with a 30 N/mm spring would need only 5.2 mm of preload, and the spring would be shorter. But it would need 25.7 bar to reach full lift, almost three times the allowed rise.
Tolerances: what moves the set pressure
For the example spring, small differences in the spring or the seat move the opening pressure as follows:
| Change on its own | Force change at installed length | Set pressure change |
|---|---|---|
| Free length 0.5 mm longer | +5.2 N | +3.3 % |
| Free length 0.5 mm shorter | −5.2 N | −3.3 % |
| Spring rate 5 % high | +7.9 N | +5.0 % |
| Spring rate 5 % low | −7.9 N | −5.0 % |
| Spring relaxes, 2 % load loss | −3.1 N | −2.0 % |
| Seat diameter 0.05 mm larger | none | −1.0 % |

Three practical rules follow:
- Specify force at the installed length, for example 157 N ± 3 N at 45.0 mm, plus a second force near full lift. Free length and rate then become reference values. Our spring preload guide explains how to put preload on a drawing.
- Leave adjustment in the valve. An adjusting screw lets the valve maker trim each valve on the test stand, so the spring only has to land the set pressure within the screw’s range. The set is then sealed; to prevent tampering, most standards require a sealing provision on the valve after setting [5].
- Check one spring range per set pressure band. Because preload deflection is limited by the spring’s length and solid height, one spring covers only a band of set pressures. Valve makers usually keep several springs for one valve size.
Relaxation, temperature and material choice
A relief valve spring sits compressed for months or years and must still deliver its force when called on. Two effects reduce that force:
- Relaxation, a slow loss of load under constant deflection, which rises with stress and temperature;
- Corrosion, from fluid that collects on the outlet side. One valve maker’s guidance warns that fluid collecting downstream of a safety valve impairs its performance and causes corrosion of the spring and internal parts [6].
Each 1 percent of load lost lowers the set pressure by 1 percent. Designers limit it with a low working stress, presetting the spring (compressing it beyond its working length so it takes its set before installation), and a wire suited to the temperature and medium:
| Option | Where it fits | What to weigh |
|---|---|---|
| Music wire | Small pilot, check and relief springs at room temperature | High strength in fine sizes; needs a finish |
| Chrome silicon or chrome vanadium | Medium springs in hydraulic oil and warm service | Better relaxation resistance than plain carbon wire |
| Stainless 302/304, 316 or 17-7 PH | Water, steam condensate, food and corrosive media | Corrosion resistant; lower strength than carbon wire |
| Nickel alloys such as Inconel X-750 | Hot gas and high-temperature service | Holds load at temperature; higher material cost |
Our high temperature springs guide gives temperature limits for each wire and how much load each loses.
Ends, squareness and guiding
The spring pushes on the poppet through its end coil. If the end is not square to the axis, the force is off-centre and the poppet is pushed sideways. That can cause seat leakage, uneven lift and wear on the guide. For relief valve springs:
- use closed and ground ends so the bearing face is flat and square; our article on spring end types compares end forms and solid heights;
- state a squareness limit on the drawing, as an angle or an offset over the free length;
- leave diametral clearance on any guide pin or bore, because the coil diameter grows slightly as the spring is compressed.

Check valve and regulator springs
Check valve springs are much lighter (our check valve springs guide works through cracking pressure and spring sizing in detail). They only need to close the valve and hold it against back flow, so the cracking pressure is small. As an example, a 15 mm seat (176.7 mm²) with a 0.35 bar cracking pressure needs only about 6.2 N; at 0.5 bar it needs 8.8 N. These springs are often small stainless compression springs or conical springs, and the same force-balance rule applies. A light spring keeps the pressure drop through the open valve low.
Pressure regulator springs work against a diaphragm or piston to hold a downstream pressure. Here the rate sets the “droop”, how far the outlet pressure falls as flow increases, so a soft spring is again preferred. Regulators often come with several interchangeable springs, each covering one outlet pressure range.
What to send for a relief valve spring quote
- Drawing or sample, with wire diameter, outside or inside diameter, free length, total coils and end type.
- Force at installed length with a tolerance, and a second force at full lift.
- Rate limit or the allowed overpressure, seat diameter and lift, if you want us to check the design.
- Space: bore or guide diameter and the solid height limit.
- Medium and temperature: fluid, temperature range and any corrosive conditions.
- Material and finish, or the wire standard your valve code requires.
- Presetting and testing: whether the springs must be preset, and the load test and records you need per batch.
- Quantity, with samples for your valve test stand first.
We make compression springs to drawing or sample, from small pilot springs to heavy springs, with ends ground on our own grinding machines and load checked against the agreed control plan. Our compression portfolio includes a compressor valve spring, and material certificates and inspection reports are available as agreed at project setup. See our compression springs range and our hydraulics springs page, read more about us, or send your drawing through our contact page. This guide was compiled by our editorial team with our spring engineers.
Frequently asked questions
What does the spring do in a relief valve?
It holds the poppet, disc or ball on the seat. The valve opens when inlet pressure times seat area exceeds the spring’s installed force. As the valve opens further, the spring compresses more and its force rises, so pressure must keep rising to open the valve fully.
How do you calculate relief valve spring force?
Multiply the set pressure by the seat area. For a 10 mm seat at 20 bar, the area is 78.5 mm² and the force is 2.0 MPa × 78.5 mm² = 157 N. That force is specified at the spring’s installed length.
Why do relief valves use soft springs?
A soft spring adds less force per millimetre of lift, so the pressure rise between opening and full lift stays small. In our example, a 10.45 N/mm spring keeps the rise to 10 percent, while a 30 N/mm spring would need 28.6 percent.
Can I change the set pressure by changing the spring?
Within the adjusting screw’s range, the set pressure is changed by adjusting the preload. Beyond that range, a different spring is needed. On a certified safety valve, only the valve maker or an authorised repairer should change the spring or the setting, and the valve must then be retested and resealed.
Why does a relief valve’s set pressure drift down over time?
Usually because the spring has relaxed or corroded. Each 1 percent of spring force lost lowers the opening pressure by about 1 percent. Low working stress, presetting and a wire suited to the temperature and medium keep the drift small.
References
- Spirax Sarco, “Safety Valves” (Learn about steam). https://www.spiraxsarco.com/learn-about-steam/safety-valves/safety-valves
- Wikipedia, “Relief valve”. https://en.wikipedia.org/wiki/Relief_valve
- Spirax Sarco, “Alternative Plant Protection Devices and Terminology”. https://spiraxsarco.com/learn-about-steam/safety-valves/alternative-plant-protection-devices-and-terminology
- Shigley’s Mechanical Engineering Design, Chapter 10 Mechanical Springs, lecture slides, Istanbul Technical University. https://web.itu.edu.tr/~halit/Makel/Ch_10_slides_m.pdf
- Spirax Sarco, “Safety Valve Selection”. https://www.spiraxsarco.com/learn-about-steam/safety-valves/safety-valve-selection
- Spirax Sarco, “Safety Valve Installation”. https://www.spiraxsarco.com/learn-about-steam/safety-valves/safety-valve-installation