In this article
- Key takeaways
- What is spring preload?
- Compression springs: preload from the installed length
- Extension springs: initial tension plus stretch
- Torsion springs: preload angle
- How to choose the preload
- Preload and tolerances
- Preload loss: set and relaxation
- How preload is checked
- Spring preload calculator
- What to put on the drawing or RFQ
- Frequently asked questions
- About the authors
- Sources
Cover image: an AI illustration based on a photograph of one of our compression springs, shown installed in a new setting.
Spring preload is the force (or, for a torsion spring, the torque) a spring already applies when it is installed and the mechanism is at rest. For a compression spring it is the rate multiplied by how far the spring is squeezed on assembly: F1 = k × (L0 − L1). A spring with a rate of 4 N/mm, a free length of 60 mm and an installed length of 50 mm has a preload of 40 N before the mechanism moves at all. In inch units, that is a 22.8 lbf/in spring with a 2.36 in free length installed at 1.97 in, giving about 9 lbf.
Preload decides whether a valve stays shut, a latch stays closed, or a lever returns all the way to its stop. In a ball detent, preload sets the force that holds the ball in its notch; our detent springs guide shows how it works with ramp angle. It is also often the least consistent force from spring to spring, because a small free-length tolerance is a large share of a small deflection. This guide explains how preload works in compression, extension and torsion springs, how to choose and calculate it, how tolerances and relaxation change it, and how to specify it so the parts you receive behave the same as the sample you approved.
Key takeaways
- Preload is a force at a length. Compression and extension springs get it from the installed length; extension springs add the initial tension coiled into them; torsion springs get it from the angle the legs are wound up on assembly.
- Tolerance hits preload hardest. In our worked example, ±1 mm on free length moves a 40 N preload by ±10% but the 100 N working force by only ±4%.
- Specify the force, not just the length. Put the preload as a toleranced force at the installed length on the drawing and let the free length float as a reference dimension.
- Leave room below the working length. Keep the working range inside the central 75% of the travel to solid and at least 15% overrun to solid, as Shigley recommends [1].
- Plan for preload loss. High stress, heat and time relax a spring. A lower design stress, the right wire and, for statically loaded springs, presetting keep preload stable. In a spring-loaded chain tensioner, the preload deflection also decides how much force the spring loses as the chain wears.
What is spring preload?
Every spring in a mechanism has three conditions: free (not installed), installed (mechanism at rest) and working (mechanism at the end of its travel). Preload is the load in the installed condition. Engineers also call it initial load, installed load or F1, and the working load F2.

A spring with no preload starts from zero force and lets the mechanism rattle, drift or sit on its stop with no holding force. A spring with preload pushes from the first millimetre. That is why almost every functional spring is installed with some preload. A return spring holds a pedal against its stop, a check valve spring seats the valve, and a cultivator trip spring holds the shank in the soil. Our guide to relief valve springs shows how preload sets a valve’s opening pressure.
Preload is not the same as initial tension. Initial tension is a property of a close-wound extension spring, set during coiling. Preload is a property of the installation, the load at the installed length. An extension spring’s preload includes its initial tension plus the force from any stretch on assembly.
Compression springs: preload from the installed length
A helical compression spring is linear over most of its travel, so the force at any length L is:
F = k × (L0 − L)
where k is the rate and L0 the free length. The preload is the force at the installed length L1, and the working force is the force at the shortest working length L2 [1][2]. Our spring rate guide shows how k follows from wire diameter, coil diameter and active coils.

Worked example. Take a compression spring with k = 4.0 N/mm (22.8 lbf/in), L0 = 60 mm (2.36 in) and a solid height of 25 mm (0.98 in), installed at 50 mm (1.97 in) and compressed to 35 mm (1.38 in) in service.
| Quantity | Calculation | Result |
|---|---|---|
| Preload F1 at L1 = 50 mm | 4.0 × (60 − 50) | 40 N (9.0 lbf) |
| Working force F2 at L2 = 35 mm | 4.0 × (60 − 35) | 100 N (22.5 lbf) |
| Force at solid, Ls = 25 mm | 4.0 × (60 − 25) | 140 N (31.5 lbf) |
| Stroke | 50 − 35 | 15 mm (0.59 in) |
| Deflection at L2 as share of travel to solid | (60 − 35) / (60 − 25) | 71% |
| Overrun to solid ξ | 140 / 100 − 1 | 0.40 |
Two checks come from Shigley’s design guidance. The working range should sit inside the central 75% of the travel from free length to solid, because the force-deflection line is less reliable near both ends. The force at solid should be at least 15% above the working force (ξ ≥ 0.15), so the spring never goes solid in service [1]. Here the spring works between 29% and 71% of its travel and has an overrun of 0.40, so both checks pass. Our compression spring design guide covers stress, buckling and the other checks.
Extension springs: initial tension plus stretch
A close-wound extension spring does not stretch until the pull exceeds its initial tension Fi. Above that, force rises at the rate k:
F = Fi + k × (L − L0)
where L0 is the free length inside the hooks [1][3]. The preload is that force at the installed length. In the example from our extension spring guide, a spring with Fi = 14 N, a rate of about 1.89 N/mm (1.895 N/mm unrounded, as used below) and L0 = 54.4 mm is installed at 70 mm, so its preload is 14 + 1.895 × 15.6 ≈ 43.6 N (about 9.8 lbf).
Two practical points follow:
- A preload below Fi is impossible. If the required preload is less than the initial tension, the spring cannot deliver it at any length: it stays closed and pulls with at least Fi. Ask for less initial tension, or a different spring.
- Initial tension varies more than rate. It depends on the spring index [1] and on the coiling process, and stress relieving after coiling reduces it [6]. An extension spring installed with little stretch therefore has a preload that depends mostly on initial tension, which is harder to hold. A slightly longer installed stretch makes preload depend more on the rate, which is easier to control.
Torsion springs: preload angle
A torsion spring’s preload is a torque, set by how far the legs are wound up from their free position when installed:
M1 = k × θ1
where k is the torque rate (N·mm per degree) and θ1 the rotation from the free position at the installed angle [1][4]. The torsion spring in our torsion spring guide has a rate of about 8.9 N·mm per degree (0.079 lbf·in per degree), so wound up 30° on installation it has a preload of about 266 N·mm (2.35 lbf·in).
The equivalent of free-length tolerance is the free angle between the legs. If that angle can vary by ±5°, the preload of the same spring varies by about ±44 N·mm (±0.39 lbf·in), which is ±17% at a 30° wind-up. Wind-up direction matters too: a torsion spring should be loaded in the direction that closes its coils. Give the free angle and the installed angle on the drawing, and say which one is measured from which leg.
How to choose the preload
Preload should come from what the mechanism needs at rest, not from the space left over. Four questions cover most designs:
- What must the spring hold against? A part pressed onto a seat must stay there under shock and vibration. As a first estimate the preload must exceed the part’s mass times the peak acceleration, plus any fluid or friction force trying to lift it. A 0.5 kg (1.1 lb) valve under 10 g of shock needs more than about 49 N (11 lbf) to stay seated, plus a margin.
- How even should the force be? The force ratio F2 / F1 shows how much the load rises over the stroke. A low rate with a large preload deflection gives a flatter force but needs a longer spring with more coils. A high rate with little preload gives a short spring with a steep force rise.
- How much variation can the function take? If the preload must sit in a narrow band, it needs to be the toleranced characteristic on the drawing (see below), and the preload deflection should not be tiny.
- How much will it lose in service? Add margin for relaxation if the spring works hot, at high stress or for many years.
Pedal and lever return springs show how these questions play out. Among the parts we make are replacement brake pedal extension springs compatible with Mahindra tractors, replacement accelerator foot springs suitable for Massey Ferguson tractors and replacement clutch pedal springs suitable for Tata vehicles. In each case the preload has to return the pedal fully against its stop every time, while the force at full travel must stay comfortable for the driver, so the drawing needs both forces, not just one. Brand names are used only to identify compatible equipment; NorenSpring is not affiliated with these manufacturers.
Adjustable preload: shims, threaded seats and adjusting nuts
Where the preload must be set on the machine rather than by the spring alone, the installed length is made adjustable. Common methods are shims or washers under one spring seat, a threaded seat or adjusting screw, and a nut on a guide rod or tie bolt. Each changes L1, so it moves the whole force line without changing the rate. Three rules keep an adjustable design safe:
- Adjust to a force, not a turn count. Set the preload by measuring the force, or by a length worked out from the rate of the spring actually fitted.
- Check solid at the tightest setting. Every millimetre of extra preload is a millimetre less travel to solid at the working length. Repeat the overrun check with the adjustment at its limit.
- Lock the adjustment. A lock nut, a thread-locking compound or a pinned seat stops vibration from winding the preload off.
Common symptoms of the wrong preload are easy to spot. Too little gives rattle, valves that weep, parts that bounce off their seats, and pedals or levers that do not return fully. Too much gives a high operating force, a spring that goes solid before the end of travel, or stresses so high that the spring takes a set and loses the preload you designed in.
Preload and tolerances
Look again at Figure 2. A ±1 mm tolerance on free length shifts the whole force line by ±4 N. At the installed length that is ±10% of the 40 N preload. At the working length it is ±4% of the 100 N force. The smaller the preload deflection, the larger the percentage error. A spring installed only 3 mm short of free length would see ±33% from the same tolerance.

EN 15800, the European quality standard for cold-coiled compression springs, sets permissible variations for the spring force at a given length and for the free length, in quality grades [5]. The practical consequence is the same in any system: tolerance the forces that matter and let the manufacturer adjust the dimensions that produce them.
- Preferred: F1 ± tolerance at L1, and if needed F2 ± tolerance at L2. Free length, total coils and wire diameter marked as reference. The spring maker sets the free length and coil count to hit the forces.
- Avoid: free length, rate and both forces all toleranced at once. They are linked, so you are asking for more than the coiling process can hold together.
- For extension springs, tolerance the force at the installed length rather than initial tension alone.
- For torsion springs, tolerance the torque at the installed angle and give the free angle as reference.
Our compression spring testing guide shows how to turn these force windows into an acceptance plan.
Preload loss: set and relaxation
A spring holds its preload only if it does not take a permanent set. Two things cause the loss.
Set from overstress. If the stress at solid exceeds what the wire can carry, the first full compression shortens the spring permanently. A spring compressed to solid during assembly, or by an over-travel in service, can lose a large share of its preload at once. Springs that would set are commonly preset in manufacture: compressed to solid after coiling so the set happens at the factory, and the free length is then made long enough to allow for it. Gutekunst Federn’s compression spring catalogue D-001 describes the same practice, pre-setting all springs that show a setting tendency during production [6]. Presetting suits statically loaded springs; Shigley notes that it is not recommended for springs subject to fatigue loading [1], where a lower design stress is the better route.
Relaxation over time. Under a constant installed load, a spring slowly loses force. The loss rises with stress and with temperature. Lee Spring’s material table gives maximum operating temperatures of about 121 °C (250 °F) for music wire and hard-drawn carbon wire, 246 °C (475 °F) for chrome-silicon and 288 °C (550 °F) for 302 stainless [7]. A spring that sits near an engine, exhaust or heater, or must hold preload for years, needs a lower design stress or a wire rated for the temperature. Our spring wire material guide compares the options, and our guide to why springs fail covers set and relaxation in more depth.
How preload is checked
Preload is checked on a spring load tester. The spring is compressed (or stretched, or wound up) to the installed length or angle, and the force or torque is read. A few details make the reading match the assembly:
- Settle first if the drawing says so. EN 15800 includes a settling test, pressing the spring to solid before measuring [5]. If your spring is preset, agree whether test springs are pressed to solid before the force is read.
- Measure at a length, not a force. The drawing gives F1 at L1, so the tester goes to L1 and reads F1. Measuring the length at a given force folds the rate tolerance into the length reading, so the result no longer compares directly with the force window on the drawing.
- Use the right seats. A spring with ground ends sitting on a flat plate behaves differently from one sitting in a recessed seat or over a guide pin. Friction against a rod or bore also adds hysteresis.
- Extension springs: read the force at the installed length; initial tension is found by extrapolating two readings above it back to zero stretch.

In our laboratory, spring tension and compression testers measure force, rate and force at working height; automatic spring testers measure rate, free length, initial tension and compressive load; and torsion spring testers measure torque against angle. Which characteristics are checked on each lot, and how often, is agreed in the control plan for the part.
Spring preload calculator
Enter the rate, the free length and its tolerance, the installed and working lengths and the solid height. The calculator gives the preload and working force, how far the free-length tolerance moves each, and whether the working range stays clear of solid.
Compression spring preload calculator
Linear helical compression spring. Gives the preload at the installed length, the working force, how much the free-length tolerance moves both, and how close the working length is to solid.
F = k × (L0 − L). The checks follow Shigley’s guidance to keep the working range inside the central 75% of the travel to solid and to leave an overrun to solid of at least 15% (ξ ≥ 0.15). The ±10% flag on preload is a prompt to look again, not a standard limit. Stress, buckling and fatigue are not checked here; the design check calculator in our compression spring design guide covers those.
What to put on the drawing or RFQ
| Item | Example |
|---|---|
| Preload | F1 = 40 N ± 10% at L1 = 50 mm (inch drawing: F1 = 9.0 lbf ± 10% at L1 = 1.97 in) |
| Working load | F2 = 100 N ± 5% at L2 = 35 mm |
| Free length | 60 mm (reference) |
| Rate | 4.0 N/mm (reference) |
| Solid height | 25 mm maximum |
| Extension springs | Force at installed length; initial tension only if the function needs it |
| Torsion springs | Torque at installed angle; free angle (reference); wind direction |
| Presetting | “Preset to solid” if the spring is designed to be preset |
| Test condition | Settled to solid before test / not settled; type of seat |
| Operating temperature and time under load | For example 80 °C continuous, held at L1 for long periods |
| Tolerance standard | For example EN 15800 grade 2 |
If you only have a sample, send it with the installed and working lengths of the assembly and the force the mechanism needs. We can measure the sample on a load tester and propose a drawing with preload as the toleranced force. You can browse our custom compression springs, custom extension springs and custom torsion springs.
Frequently asked questions
What is spring preload?
Spring preload is the force a spring applies when it is installed and the mechanism is at rest. For a compression spring it equals the spring rate times the distance the spring is compressed from free length to installed length, F1 = k × (L0 − L1). For a torsion spring it is a torque, the torque rate times the installed wind-up angle.
How do you calculate spring preload?
Multiply the spring rate by the installed deflection. A compression spring with a rate of 4 N/mm, free length 60 mm and installed length 50 mm has a preload of 4 × 10 = 40 N. For an extension spring, add the initial tension: F1 = Fi + k × (L1 − L0). For a torsion spring, M1 = k × θ1.
Is preload the same as initial tension?
No. Initial tension is built into a close-wound extension spring during coiling and must be overcome before the coils separate. Preload is the load at the installed length. An extension spring’s preload includes its initial tension plus the force from any stretch at installation. Compression springs have no initial tension.
What is a typical spring preload?
There is no single typical value. Start from the smallest force that keeps the mechanism closed or seated, add a margin for relaxation, then check two ratios: the working force over the preload (F2 / F1), which shows how steeply the force rises over the stroke, and the free-length tolerance over the preload deflection, which shows how much the preload will vary. In the worked example above, 10 mm of preload deflection against a ±1 mm tolerance gives ±10%.
Does preload change the spring rate?
No. Preload moves the spring along its force line; it does not change the slope. The same holds for coilover spring perches, as our custom suspension springs guide explains. The rate depends on the wire, the coil diameter and the number of active coils. Preload only changes where on the line the spring sits at rest, so the force at every point of the stroke rises by the same amount. For example, if you shorten the installed length by 2 mm and keep the same stroke, both F1 and F2 rise by k × 2 mm.
Why is my spring’s preload different from the drawing?
The usual causes are free-length tolerance, which has its largest effect at small installed deflections, a spring that has taken a set after being compressed to solid, relaxation from heat or high stress, and measuring at a different length or on a different seat from the drawing. Check the free length first, then the test method.
About the authors
This guide was prepared by the NorenSpring engineering team, which designs and manufactures custom compression, extension and torsion springs and wire forms in Xuzhou, China. Technical review by Feng Yulin, General Manager and senior structural engineer, who has 15 years of spring R&D experience and more than 30 national patents. NorenSpring holds IATF 16949, ISO 9001, ISO 13485, ISO 14001 and ISO 45001 certifications. The laboratory photo is from our own plant in Xuzhou; the cover is an AI illustration based on our own product photo. The worked examples are calculations to show the method, not rated parts. Sources were last checked on October 22, 2026.
Need a spring with a stable preload? Send us your drawing or sample with the installed and working lengths, the force the mechanism needs at each, the annual quantity and the operating temperature, and we will confirm the design and the test method with the quotation.
Sources
The numbers in square brackets in the text refer to this list. Spring makers’ publications are cited by name without links.
- R. G. Budynas and J. K. Nisbett, Shigley’s Mechanical Engineering Design, 9th edition, McGraw-Hill, 2011, chapter 10 (Mechanical Springs). Source for the linear force-deflection relation, the recommendation to confine the operating range to the central 75% of the travel to solid, the fractional overrun to closure ξ ≥ 0.15, the extension spring load with initial tension, the torsion spring torque rate, and the note that presetting is not recommended for springs subject to fatigue.
- CEN, EN 13906-1:2013, Cylindrical helical springs made from round wire and bar. Calculation and design. Part 1: Compression springs. Retrieved 2026-10-22.
- CEN, EN 13906-2:2013, Cylindrical helical springs made from round wire and bar. Calculation and design. Part 2: Extension springs. Retrieved 2026-10-22.
- CEN, EN 13906-3:2014, Cylindrical helical springs made from round wire and bar. Calculation and design. Part 3: Torsion springs. Retrieved 2026-10-22.
- CEN, EN 15800:2008, Cylindrical helical springs made of round wire. Quality specifications for cold coiled compression springs. Its contents list permissible variations for spring force at a given length and for free length, quality grade coefficients, and a test load for pressing to solid (settling test). Retrieved 2026-10-22.
- Gutekunst Federn, information on extension springs (initial tension and the effect of stress relieving) and compression spring catalogue D-001 (tolerances to DIN EN 15800; springs with a setting tendency pre-set in production). Retrieved 2026-10-22.
- Lee Spring, spring materials table (maximum operating temperatures for music wire, hard-drawn, chrome-silicon and 302 stainless wire). Retrieved 2026-10-22.