Industry News 18 views

Trailer Ramp Springs: How to Size Ramp Assist Springs for Gates and Ramp Doors

Trailer ramp springs carry most of a folding gate's weight so one person can lift it. This guide explains the moment balance, shows how a two-spring assist cuts lift effort on a 45 kg gate from 206 N to 50 N, sizes the extension spring and lists what to specify.

Trailer Ramp Springs: How to Size Ramp Assist Springs for Gates and Ramp Doors
In this article
  1. Key takeaways
  2. How trailer ramp springs work
  3. Why a spring cannot follow the gate’s weight exactly
  4. Sizing a trailer ramp spring: a worked example
  5. Torsion springs on the hinge tube
  6. Material, finish and corrosion
  7. Safety: stored energy, pairs and safety cables
  8. What to send for a trailer ramp spring quote
  9. Frequently asked questions
  10. References

Cover image: an AI-generated illustration based on a photo of one of our heavy coated extension springs; the trailer is generic and not a specific product.

Trailer ramp springs are heavy extension or torsion springs that carry most of the weight of a folding rear gate or ramp door, so one person can raise and lower it without strain. They work by converting spring force into a moment about the hinge that opposes the gate’s own weight, and how well they do that depends as much on the lever geometry as on the spring specification itself.

This guide is for trailer builders, ramp and gate fabricators and parts buyers who order ramp assist springs. It explains the moment balance, shows with a worked example why the crank angle matters, sizes a matching extension spring, and lists what to put on the drawing. For general extension spring terms, see our guide on how to specify a custom extension spring.

Key takeaways

  • A gate’s weight moment is W × a × cos θ. It is largest with the gate down and zero when the gate is upright. A 45 kg gate with its centre of gravity 0.70 m from the hinge needs 206 N at its 1.5 m top edge to start lifting from the ground.
  • Springs balance a moment, not a weight. Spring force times its lever arm about the hinge must follow the cosine curve. In our example, two springs on a 150 mm crank cut the peak lift effort to 50 N.
  • Geometry can matter more than rate. Setting the same crank 20 degrees further back, with almost the same springs, cut the peak effort to 10 N, but the springs then pulled the gate shut with 27 N near closed.
  • Initial tension does real work. In the example, each spring holds 350 N before it stretches at all, and rises to 1,024 N with the gate down.
  • Plan for corrosion and failure. Ramp springs live outdoors under load. Coat them, keep stress moderate, replace them in pairs and fit a safety cable through each spring.

How trailer ramp springs work

A folding gate or ramp pivots at the rear of the trailer deck. When it is upright, its weight acts almost directly through the hinge and needs no holding force; as it comes down, its centre of gravity moves out behind the hinge and the moment it applies increases steadily. A patent on a gate-ramp spring assist describes the problem plainly: gates and ramps are usually steel, carry considerable weight, and the whole weight is supported above the pivot, so letting them down or lifting them up puts the operator’s back and arms at risk [1].

The gravity moment about the hinge is:

M_g = W × a × cos θ

where W is the gate weight, a is the distance from the hinge to its centre of gravity and θ is the gate angle above horizontal. A moment is a force times the perpendicular distance from the pivot to its line of action [2]. A spring assist adds a second moment, spring force times the spring’s lever arm about the hinge, in the opposite direction.

Side-view schematic of a trailer gate hinged at the deck with a 45 kg weight acting 0.70 m from the hinge, a 150 mm crank arm at the hinge and an extension spring running forward to an anchor on the trailer frame
Geometry of a lever-and-spring ramp assist. The crank sets how the springs’ lever arm changes as the gate moves. Tap or click the figure to enlarge.

There are three common layouts on trailers:

Layout Where the spring sits Spring type Notes
Lever and spring Along the side rail or under the deck, pulling a crank or lever plate at the hinge Extension spring with hooks or loops Most common on open utility trailer gates; easy to replace
Cable and pulley On the door frame or sidewall, connected to the ramp door by a cable Extension spring Typical of enclosed cargo trailer ramp doors; the cable path sets the lever arm
Hinge tube Wound around the hinge axis, legs fixed to frame and gate Torsion spring Compact and hidden; needs a tube and a winding procedure

Whichever layout you use, the job is the same: make the spring moment follow the gravity moment as closely as you need across the gate’s travel.

Why a spring cannot follow the gate’s weight exactly

The gravity moment falls with the cosine of the gate angle, while a spring’s force falls linearly as it shortens and its lever arm about the hinge changes with the crank position. The two curves never match exactly, so every ramp assist is a compromise in which the designer decides where the remaining effort sits and how large it is. For example, a builder may accept a heavier feel at mid-travel in exchange for a gate that never rises by itself.

For this guide we modelled one gate and changed only the springs and the crank angle. The gate is 1.5 m tall, weighs 45 kg and has its centre of gravity 0.70 m from the hinge. Each side has one extension spring anchored 600 mm forward of the hinge and pulling a 150 mm crank arm. Lift effort is the force needed at the top edge of the gate, ignoring hinge friction.

Line chart of lift effort against gate angle: no springs falls from 206 N with the gate down to 0 when closed, design A peaks at 50 N, design B stays at or below 10 N but goes negative to minus 27 N at closed
Lift effort at the top edge of a 45 kg, 1.5 m gate. Design A puts the crank in line with the springs when the gate is closed; design B sets the crank 20 degrees back. Tap or click the figure to enlarge.
Gate angle Gravity moment Effort, no springs Effort, design A Effort, design B
0° (down) 309 N·m 206 N 7 N 8 N
20° 290 N·m 193 N 31 N 6 N
40° 237 N·m 158 N 48 N 10 N
50° 199 N·m 132 N 50 N 10 N
60° 155 N·m 103 N 46 N 8 N
80° 54 N·m 36 N 19 N −10 N
90° (closed) 0 N·m 0 N 0 N −27 N

Two practical lessons come out of this model. First, a well-designed assist removes most of the effort but deliberately not all of it. Design A, two 4.0 N/mm springs with 350 N initial tension, cuts the peak from 206 N to 50 N. The gate still rests on the ground with 7 N at the top edge, so it stays down when loading.

Second, crank angle changes the shape of the curve more than spring rate does. Design B uses springs of almost the same rate, 4.25 N/mm with 300 N initial tension, but sets the crank 20 degrees further back. Peak effort drops to 10 N, which feels almost weightless. Near closed, though, the effort turns negative. The springs then pull the gate shut with 27 N at its top edge, so the latch has to resist that and the gate can swing up hard once it passes 70 degrees. Many builders prefer something like design A, with a little positive effort everywhere, because the gate never moves on its own.

Sizing a trailer ramp spring: a worked example

Once the geometry is set, the spring requirement follows from it. For design A, each spring sits at 450 mm between its anchor and the crank pin with the gate closed, and stretches to 618.5 mm with the gate down. The spring must therefore:

  • hold its initial tension of 350 N at a free length of 450 mm between attachment points,
  • stretch 168.5 mm,
  • reach 1,024 N at full stretch, and
  • do this at a rate of 4.0 N/mm.
Line chart of force in one ramp spring against gate angle: 350 N of initial tension with the gate closed rising to 1,024 N with the gate down
Force in each spring for design A. The spring never drops below its initial tension, so it stays tight on its hooks. Tap or click the figure to enlarge.

The same data in table form, for checking against your own calculation:

Gate angle Spring length Extension Force per spring Spring moment, both springs Gravity moment
0° 618.5 mm 168.5 mm 1,024 N 298 N·m 309 N·m
10° 593 mm 143 mm 921 N 275 N·m 304 N·m
20° 567 mm 116 mm 816 N 244 N·m 290 N·m
30° 541 mm 91 mm 713 N 206 N·m 268 N·m
40° 517 mm 66 mm 616 N 164 N·m 237 N·m
50° 495 mm 45 mm 528 N 124 N·m 199 N·m
60° 476 mm 26 mm 454 N 86 N·m 155 N·m
70° 462 mm 12 mm 398 N 53 N·m 106 N·m
80° 453 mm 3 mm 362 N 25 N·m 54 N·m
90° 450 mm 0 mm 350 N 0 N·m 0 N·m

We sized the spring with the standard helical spring equations [3]. Rate is k = G d⁴ / (8 D³ Na), and body stress is τ = Kw × 8 F D / (π d³), where Kw is the Wahl factor. We chose oil-tempered wire to ASTM A229, with a shear modulus of 77.2 GPa and a minimum tensile strength of about 1,289 MPa at 7 mm from the Shigley strength equation [3].

Parameter Value How it was found
Wire diameter d 7.0 mm Smallest size that kept body stress near one third of tensile strength
Mean coil diameter D 49 mm (outside diameter 56 mm) Spring index C = D/d = 7
Active coils Na about 49 Na = G d⁴ / (8 D³ k) for k = 4.0 N/mm
Body length about 352 mm (Na + 1) × d, close wound
Ends One full loop each end, about 49 mm inside Gives about 450 mm between attachment points
Initial tension 350 N Inside the achievable range of 240 to 369 N for C = 7
Force at full stretch 1,024 N at 168.5 mm 350 + 4.0 × 168.5
Body stress at full stretch 452 MPa 35 % of tensile strength
Hook bending stress (point A) about 860 MPa 67 % of tensile strength; check against your fatigue requirement
Hook torsion stress (bend radius 2d) about 466 MPa Tighter bends raise this quickly

Three points are worth noting. First, initial tension is limited by the spring index. For C = 7, the achievable range is roughly 240 to 369 N for this wire, so a design calling for 500 N of initial tension would need a lower index or a heavier wire [3].

For 7 mm wire, the achievable initial tension by spring index is:

Spring index C Mean diameter Initial stress range Initial tension range
5 35 mm 111 to 162 MPa 428 to 624 N
6 42 mm 99 to 147 MPa 316 to 473 N
7 49 mm 87 to 134 MPa 240 to 369 N
8 56 mm 77 to 122 MPa 186 to 293 N
9 63 mm 69 to 111 MPa 147 to 237 N

Second, the hooks are more highly stressed than the body. At full stretch, bending at the base of the loop reaches about two thirds of tensile strength, almost double the body stress. That is why ramp springs usually break at a hook, and why the hook form and its bend radius belong on the drawing. Third, the stretch is 48 percent of body length, comfortable for a close-wound spring, but the maximum length must be checked so the spring never runs out of travel if the gate drops past its usual rest position.

Heavier gates scale up quickly. For example, doubling the gate moment roughly doubles the required spring force, which pushes the wire towards 9 mm or calls for four springs instead of two. A longer crank arm lowers the force but increases the stretch, so the body gets longer. These trade-offs are the reason we ask for the gate weight, hinge geometry and available space before we propose a spring.

This quick-reference table uses the same crank geometry as design A, an effective lever arm of 145.5 mm with the gate down, and balances 95 percent of the gate moment in that position. Treat it as a starting point; your own hinge geometry will change the numbers.

Gate mass CG from hinge Moment, gate down Effort at 1.5 m top edge, no springs Force per spring, 2 springs Force per spring, 4 springs
30 kg 0.60 m 177 N·m 118 N 576 N 288 N
45 kg 0.70 m 309 N·m 206 N 1,009 N 504 N
60 kg 0.75 m 441 N·m 294 N 1,441 N 721 N
80 kg 0.80 m 628 N·m 419 N 2,050 N 1,025 N
100 kg 0.85 m 834 N·m 556 N 2,722 N 1,361 N
120 kg 0.90 m 1,059 N·m 706 N 3,459 N 1,729 N
150 kg 1.00 m 1,472 N·m 981 N 4,804 N 2,402 N
Heavy black coated extension spring with a large hook end standing upright on a display table
A heavy black coated extension spring from our range, shown at an exhibition. Springs of this type suit gate and ramp assist duty.

Torsion springs on the hinge tube

A torsion spring wound around the hinge axis can do the same job without a crank or an exposed extension spring. Its moment rises in a straight line with the angle it is wound through, so it again only approximates the cosine curve. The spring is preloaded so that it gives most of its moment with the gate down and little near closed.

Torsion designs suit enclosed ramp doors and gates where a hidden spring is preferred. They need a hinge tube or shaft to support the coils, legs fixed firmly to the frame and the gate, and a safe procedure for winding the preload. Leg shape and the wind direction relative to the load are the usual sources of error, so both must be on the drawing. Our guide on how to specify a custom torsion spring covers leg angles, wind direction and torque tolerance in detail.

Material, finish and corrosion

Trailer springs operate outdoors, are splashed with road water and de-icing salt, and often remain stretched for weeks, so material and finish selection deserve the same attention as the force calculation. For most sizes a hard-drawn or oil-tempered carbon spring wire is the economical choice. Our comparison of oil tempered and hard drawn spring wire explains the difference.

Finish Corrosion protection Points to check
Zinc plating with passivate Good for general road use Electroplated high-strength springs must be baked after plating to reduce the risk of hydrogen embrittlement [4]
Powder coating (black, red, other colours) Good barrier while the coating is intact Coating thickness adds to the outside diameter; chips at the hooks start rust
Zinc flake coating Strong protection without electroplating Usually specified by coating system and layer thickness
Pre-galvanised wire Good, continuous zinc layer Availability depends on wire size and grade

For black, red and other coloured coatings, a coloured powder coat over phosphate is common on gate springs. Our spring finishes guide compares these options and explains how to write them on a drawing. Whatever the finish, keep the working stress moderate, because corrosion pits at the hook are where most outdoor springs start to crack.

Safety: stored energy, pairs and safety cables

A ramp spring holds considerable energy when stretched. In design A, each spring stores about 116 J of extra energy with the gate down, enough to throw a hook or a broken coil with force. Good practice for builders and users includes:

  • Fit a safety cable through each spring. A cable running through the centre of the spring and anchored at both ends keeps the pieces in place if the spring breaks. The gate-ramp assist patent cited above uses a flexible safety cable through the spring for this reason [1].
  • Replace springs in pairs. A new spring on one side and a tired one on the other loads the gate unevenly and twists the hinge.
  • Release the load before removing a spring. Support the gate in the position where the spring is shortest, usually closed, before unhooking it.
  • Inspect the hooks. Cracks, rust pits and opened hooks are the signs that a spring should come off. Our article on why springs fail shows the common failure patterns.
  • The same rules apply to the heavy extension springs on a plow blade. Our snow plow trip springs guide covers paired replacement and safe adjustment there.

What to send for a trailer ramp spring quote

To quote a ramp assist spring, or to check whether a design will balance your gate, we need:

  1. Gate data: weight, height and the distance from the hinge to its centre of gravity, or the gate drawing.
  2. Hinge geometry: spring anchor position, crank or lever length and angle, or the cable path for ramp doors.
  3. Lengths and forces: the spring length with the gate closed and with it fully down, and the force you want at each.
  4. Space: maximum outside diameter and any clearance limits along the rail.
  5. Ends: hook or loop type and orientation, and the pin or eye bolt diameter they fit on.
  6. Material and finish: wire grade if specified, and the colour or coating system.
  7. Quantity, with samples for a trial fit first.

We make heavy extension springs and torsion springs to drawing or sample, and can check the spring against your gate geometry before tooling. Material certificates and inspection records are available as agreed at project setup. See our extension springs range, read more about us, or send your gate data through our contact page. This guide was compiled by our editorial team with our spring engineers.

Frequently asked questions

How do I know what size trailer ramp springs I need?

Start from the gate, not the spring. Measure the gate weight and the distance from the hinge to its centre of gravity, then the spring length with the gate closed and fully down. The spring force needed with the gate down is roughly the gravity moment divided by the springs’ lever arm in that position. For a 45 kg gate with its centre of gravity 0.70 m from the hinge, that moment is 309 N·m.

Should trailer ramp springs make the gate weightless?

Usually not. A gate that is fully balanced can float upwards when unlatched or slam closed near the top of its travel, so most builders leave a small positive effort at every angle and the gate stays where the operator leaves it. In our example, design A leaves a peak of 50 N at the top edge and 7 N with the gate on the ground.

Why do trailer ramp springs break at the hook?

The hook experiences bending as well as torsion, so its stress is considerably higher than in the coils. In our worked example the hook reached about 860 MPa against 452 MPa in the body. Corrosion pits at the bend and sharp bend radii make this worse.

Can I use one stronger spring instead of two?

You can, but a single spring on one side twists the gate and hinge. Two springs, one on each side, keep the load even. Using two also means that if one breaks, the other still supports part of the gate.

What is the difference between ramp springs and ramp torsion springs?

Ramp springs usually means extension springs that pull a lever or cable. Ramp torsion springs are wound around the hinge axis and twist rather than stretch. Both create a moment about the hinge; the torsion version is more compact but needs a hinge tube and a safe winding procedure.

References

  1. Licata, K. R. and Licata, C. L., “Trailer gate-ramp lift spring assist apparatus”, US Patent 6,485,004 B1, granted 26 November 2002 (Google Patents). https://patents.google.com/patent/US6485004B1/en
  2. Wikipedia, “Torque”. https://en.wikipedia.org/wiki/Torque
  3. Shigley’s Mechanical Engineering Design, Chapter 10 Mechanical Springs, lecture slides, Istanbul Technical University. https://web.itu.edu.tr/~halit/Makel/Ch_10_slides_m.pdf
  4. Wikipedia, “Hydrogen embrittlement”. https://en.wikipedia.org/wiki/Hydrogen_embrittlement

COMMON QUESTIONS

Answers Before You Ask

Clear answers to common purchasing questions.

Still have questions?
Can you manufacture from my drawing without a standard part number?

Yes. Most of our projects start from a customer drawing or application sketch. We review the geometry, material and performance needs, then confirm manufacturability before quoting.

What is your minimum order quantity?

We support both small-batch prototypes and high-volume production. There is no fixed MOQ — quantities are evaluated based on the spring type, tooling and material requirements.

How do you handle springs for high-temperature or corrosive environments?

We select materials (such as Inconel, stainless steel or special alloys) and surface treatments matched to the operating environment. Our engineers can recommend options based on temperature range, media exposure and cycle life.

What documentation can you provide with production orders?

We supply inspection reports, material certificates, dimensional records and traceability documentation as agreed during project setup. PPAP and FAIR packages are available for automotive and aerospace programs.

What is the expected lead time?

Lead time depends on the spring type, material, tooling, quantity and approval requirements. We confirm the production and sample schedule during quotation.

How are payment and delivery terms confirmed?

Commercial terms, delivery address and documentation requirements are confirmed with the quotation before production starts.

What support is available after delivery?

After-delivery questions can be routed through the project contact for drawing questions, quality documents, repeat orders and application feedback.

Can you provide samples before mass production?

Yes. Prototype and pre-production samples can be arranged for dimensional, load and application approval before the full production order proceeds.